Sg driver netbackup ports

The two major manufacturers of fc hbas are qlogic and emulex and the drivers for many hbas are distributed inbox with the operating systems. Determining if the netbackup sg driver is installed. Windows server backup tcp ip port solutions experts. Tcpportsusedbynetbackup compatibilitywithbacklevelhosts tcp ports used by netbackup. We update the list on a regular basis, however if you feel we should add other ports. Netbackup media manager provides its own driver for communicating with scsicontrolled robotic peripherals. The standard nfs ports, 2049 and 111 must be open inbound from the clients so that they can mount the nfs shares. What is a driver, device file, device path in netbackup vox. Capabilities provided by scsi port windows drivers. Driver sg successfully added to system but failed to attach warning. Installingreinstalling the sg and the st drivers veritas. Please see the netbackup backup planning and performance tuning guide in the appendix for detailed information on sizing a netbackup environment. As a precaution you may wish to copy the files includescsi sg. Hello, i configured a linux vm with mhvtl an open source vtl and tgt an iscsi target daemon.

It occurs when commands with data transfer lengths that are either odd or zero length, are sent while scatter gather is being used for the default buffer. Sybase sql anywhere database netbackup catalog has been upgraded to version 12. In this post i will explain what netbackup san client is and how to configure it. Im trying to configure a solarix 10 x86 vm with netbackup 7. So while configuring a new robot what actually does a device file and device path refer to. If os found the drive and device files are created we can reconfigure sg driver for netbackup. Installation and upgrade checklist report for commandcentral storage management server ccsms 5. Firewalls sometimes affect system communications between a media server and remote systems that reside outside the firewall environment. The scsi disk driver sd, once device initialization is complete, only sends scsi read and write commands. A surebackup job is a task for recovery verification. A san client is a special netbackup client that can back up large amounts of data rapidly over a. This list a very small part of our sg ports database includes tcpudp ports currently tested by our security scanner, and corresponding potential security threats. Netbackup ft media servers accept connections from san clients and send data to the disk storage.

Installation and upgrade checklist report for nbups 7. To manage the sg driver perform the following steps as the root user. You may have special port requirements for backup exec if you use a firewall. The surebackup job aggregates all settings and policies of the recovery verification task, such as application group and virtual lab to be used, vm backups that must be verified in the virtual lab and so on. The copilot feature requires the tcp port for 8446 to be open inbound to the netbackup appliance from the master server to manage the nfs shares. Install and configure multiple network ports on the netbackup media servers. So i need to know what network access should exist to backup and restore database tofrom nb server.

Netbackup 5200 and 5220 appliance ports for firewall between master and media server table 33 inbound ports continued source destination port service description. The host bus adapters hbas that accept connections from the san clients use a special netbackup target mode driver to process ft traffic. Earlier versions of the sg device driver either have no version number e. Symantec netbackup san client and fibre transport guide unix, windows, linux release 7. Issuing the telnet command telnet domainname or ip port will allow you to test connectivity to a remote host on the given port. This driver is called the scsa generic scsi passthru driver, also referred to as the sg driver. Thank you everyone actually i am new to netbackup, i have basic understanding of those terms but with respect to netbackup while configuring new devices i am getting a bit confused. The nf file must be rebuilt in order to allow the os to see those additional luns. Netbackup snmpserver 162 snmptrap opscenterserver allowbetweensource anddestination bidirectional.

For complete information about setting up a firewallsecure acsls server, refer to your vendor documentation. The scsi passthrough driver sg driver on solaris allows scsi commands to be. Connect a fibre channel hba port on each netbackup media server to a. About the netbackup network ports thischapterincludesthefollowingtopics. Netbackup mailserver 25 smtp opscenterserver allowfromsourceto destination. The sg driver permits user applications to send scsi commands to devices that understand them.

How to backup and restore device drivers in windows 10 8. The following table summarizes the different versions of the sg device driver that are available. If you are using a network firewall or hostbased firewall e. The standard enterprise linux releases have the sg and the st modules available for loading.

This driver is called the scsa generic scsi passthrudriver, also referred to as the sg driver. If you wish to use one of these tarballs then untar it in usrsrclinux or wherever the top of your kernel tree is. A netbackup ft media server is a netbackup media server on which the fibre transport services are activated. This command is used to configure the web ports for the web services layer wsl application on the master server. How to check fibre channel hbas in linux open tech guides. The drivers that support this new interface have a major version number of 3. Using iscsi initiator from a windows host works fine, and netbackup can use virtual drives to backup data.

This port number must match the port number that you specify in the netbackup nf file. The bsg driver has device names of the form devbsg0. How to confiugre tape library in linux master serv. The bsg driver also supports the sg version 4 interface which at this time the sg driver does not. Select a device from the device tree, rightclick on it and select update driver software from the dropdown menu. Protecting sparc superclustertape backup with symantec. Since netbackup is depreciating the ovpass driver for the medium changer. Veritas and the veritas logo, and netbackup are trademarks or registered trademarks of. The scsi port driver provides the following capabilities. One of the biggest perks of telnet is with a simple command you can test whether a port is open. The new netbackup status code 2111 has been added to this release with the. The product information label contains your serial number and product number. It also includes target entries for three storedge network foundation hba ports. Fast and userfriendly free tool for driverss backup, restoration and removal with command line options, automatic restoration from cd\dvd and path.

However, being extremely happy with the prototypes, and having them save my neck a few times backing up is a good idea, i decided not to abandon the project. What ports need open from netbackup server to client. If needed, install an appropriate silicon labs cp210x usb to uart bridge driver on the workstation used to connect with the system. Symantecs fileconnect software download portal has being decommissioned and has been replaced by the software download capability in mysymantec. You can find it either on the back of your laptop, inside the battery compartment or under the cover on the back of the laptop. Symantec netbackup san client and fibre transport guide. Find answers to windows server backup tcp ip port from the expert community at experts exchange.

Getting sg driver working with iscsi target on a s. Play back and record with any daw using a soundgrid io, as part of a soundgrid audio network in this case the soundgrid driver serves as your asiocore audio playback engine. Click on browse to find the location of the driver files you backed up previously and click next. Connect nonsoundgrid ios to the soundgrid network for plugin processing and mixing using the driver s. Backup driver restore driver preserve driver driver backup restore restrain. Click mysymantec login required below to be redirected to the new portal, then navigate to the my products tab to take advantage of the new experience. For information about how to configure the driver, see the netbackup device configuration guide, available at the following url. Fibre channel fc host bus adaptershba are interface cards that connects the host system to a fibre channel network or devices.

Install the driver a silicon labs cp210x usbtouart bridge driver is used to provide access to the console, which is exposed via the miniusb port on the appliance. The soundgrid driver connects your mac or pc to soundgrid ios and the soundgrid audio network. Configuration recommendations, netbackup, infoscale, storage foundation. Installation and upgrade checklist report for ccsms 5.

Client systems require the scsi generic sg driver and. Fast and userfriendly free tool for driverss backup, restoration and removal with command line options, automatic restoration from cd\dvd and path formatting. You can run the surebackup job manually or schedule it to run automatically. Sg1 user commands sg1 name top sg execute command as different group id synopsis top sg group c command description top the sg command works similar to newgrp but accepts a command. Veritas netbackup san client and fibre transport guide. This driver allows passthrough commands to scsi tape drives and control of robotic devices scsi tape st driver. What is san client in netbackup and how to configure it. To fix that problem symantec suggested rebuilding the sg driver and told me to remove everything from devrmtcbn and. To configure an acs robot in an oracle storagetek acsls firewall environment, use the. Basically, this is the same driver as pcl5e with color printing functionality added. Using telnet to test open ports the complete howto. Microsoft windows supports systems that contain different types of io buses andor several io buses of the same type. Client systems require the scsi generic sg driver and passthrough device files.

728 1406 117 418 683 488 1306 96 716 1387 285 826 1135 467 525 70 1157 1325 1377 1297 536 956 631 54 870 1149 727 922 560 445 313 806 1393